故障维修,troubleshooting
1)troubleshooting故障维修
1.Troubleshooting for malfunctions of REVOLUTION~(TM)XR/d DR systemREVOLUTION~(TM)XR/d DR系统故障维修
2.This paper decribes a case of troubleshooting for it.本文介绍了该仪器的一例故障维修
英文短句/例句

1.The three cases of faults maintenance about GE Prospeed AIGE Prospeed AI故障维修3例
2.CThe maintenance of Johnson Vitros350 Dry-biochemical analyzer强生Vitros350干式生化分析仪MALFUCTION故障维修
3.The three case of maintenance of Draeger SAVINA respirator德尔格SAVINA呼吸机故障维修3例
4.Troubleshooting for common breakdowns of Boehringer Mannheim KEYSYS biochemical analyzer宝灵曼KEYSYS生化分析仪常见故障维修
5.Two Cases of Troubleshooting for Fresenius 4008S Hemodialysis System费森尤斯4008S血液透析机故障维修两例
6.Troubleshooting of Artifact of Toshiba Aquilion 64-Slice CT东芝Aquilion 64排CT伪影故障维修
7.Troubleshooting of Philips Brilliance 16-Slice CT飞利浦Brilliance 16排CT故障维修三例
8.Troubleshooting of Siemens Servo 900C Ventilator西门子Servo 900C呼吸机气路压力故障维修
9.Troubleshooting of Gambro AK95 Hemodialysis System金宝AK95血透机自检低压故障维修
10.Troubleshooting of GE Revolution XR/d DRGE Revolution XR/d DR旋转阳极故障维修一例
11.Troubleshooting of the Software of Siemens DRH CT西门子DRH CT机软件故障维修一例
12.Two Cases of Troubleshooting for AC.diff Blood Cell Counter库尔特AC.diff血球计数仪故障维修二例
13.Work principle of System Four power station and trouble maintenanceSystem Four电源站的工作原理及故障维修
14.Fault Diagnosis and Maintenance of the Micro- Computer微机故障诊断与维修
15.REPAIRING NOISE OR DISTORTION FROM ONE SPEAKER维修噪音或一个扬声器的断开故障
16.It has easy operation, low breakdown rate and quick service.本机操作简便、故障率低、维修容易。
17.5 Detective Analysis and Maintenance of 24 Pin Printing Driving Circuit Failures24针打印驱动电路故障测试与维修
18.Common Malfunction Checking,Measurement and Maintenance about Digital/Video Frequency Revelation Desk;数字/视频展示台常见故障检测与维修
相关短句/例句

breakdown maintenance故障维修
1.Principle and breakdown maintenance of engine automation measurement equipment for bench test;发动机性能自动测试设备原理及故障维修
3)fault repair故障维修
1.Radar counter measurement equipment is very complicated,there are a lot of probloms in its daily maintenances and fault repair,such as complicated and time consuming fault testing process,and it is also very difficult and expansive to repair.雷达对抗装备是一种复杂的电子设备,其日常维护管理、故障维修存在着故障测试流程复杂、测试时间长、维修困难、维修费用高等问题,这些问题严重影响和制约部队的日常训练和作战使用。
4)Fault Maintenance故障维修
1.Fault Maintenance on PMC Section of CNC Machine with FANUC System;FANUC系统数控机床PMC方面的故障维修
5)failure maintenance故障维修
1.Decision on failure maintenance for aircraft automatic join-assembly system飞机自动化对接装配系统的故障维修决策
6)trouble shooting故障维修
延伸阅读

DCS—50型电子定量包装秤常见故障检修DCS—50型电子定量包装秤计量准确度高,稳定性好,包装速度快,广泛应用于制糖及化工行业。现把该秤常见故障的检修介绍如下:  一、部件组成  该秤主要由电气和气动两部分组成。电气部分采用MCS—51单片机系统和XK3113数字显示件相结合,以P8031为中心,该系统的故障率很低;气动部分由加料主气缸、放料气缸、夹袋气缸和电气换向阀组成,由于连续运行,其故障率占到80%左右。  二、常见故障检修  1夹袋机构不动作。说明电气转换阀没有正常工作,在气源气压正常情况下,首先检查换向阀线圈电压(24伏)是否能被控制,若电气转换正常则为换向阀故障,应更换,如果不能切换,对应的检修流程为夹袋开关、换向阀控制三极管、双向触发器(CD4013)光电耦合器。  2重量显示不稳定,时好时坏。首先应该排除秤体震动现象,检查+5V系统供电电压是否稳定,秤体接地电阻是否符合要求。  3料斗漏糖。料斗漏糖与放料机构故障有直接关系,清除斗内积糖,观察放料气缸是否到位,关门阀是否有积糖。如以上均正常,则应检查放料气缸密封性是否良好。在此气缸下部有一阻尼调整螺丝,当调整螺钉气孔堵塞时,会出现关门延时,而出现漏糖。疏通气孔后,最佳的调整方法是:及时关门,响应时间要短,又要保证具有良好的阻尼,否则,关门机构过量冲击料斗,造成数字显示不稳定,且机械手磨损快。  4下料重量不稳,超差现象严重。该秤三联件中有一储油杯,气源通过油杯,带动润滑油进入各气缸及换向阀,主要作用一是润滑缸体,二是加强密封性能。当油路堵塞时,会造成气缸密封橡胶垫圈与缸体干磨,而出现破损,造成串气,影响气缸各级加料行程,通过更换主气缸两级橡胶垫圈,一般都能奏效,但同时应疏通油路。另外,该三联件上还设有一油量调整螺钉,如调整过大,也会造成润滑油直接外排而浪费;过小则起不到作用。具体调整应为每7天左右一杯油。  5放料过程中缺少某一级加料过程。下料过程中缺少某级加料过程时,应仔细观察主气缸的到位情况,Q1,Q2,Q3,电气换向阀分别控制气源至主气缸电位的高低,应根据故障现象检查其对应的换向阀,Q1,Q2,Q3,分别负责一、二、三级加料过程气源的供给。在更换换向阀时,应将它的两种工作状态旋至“0”位。在排除了换向阀的原因后,进一部检查信号接口电路,各自的信号由光电耦合器输出至控制三极管,参数为BV>60V,Zcm>3A,Pcm>40W的达林顿管。  6不能启动自动程序。首先检查放料气缸是否关闭,在气缸关闭的情况下,位置传感器是否松动、到位。位置传感器实际上就是一干簧开关,靠气缸内环形永磁体来实现关与开。当传感器位置不正确,气缸内永磁体磁性减弱都会引起信号失控,而出现自动程序不启动。在调整传感器位置无效时,可做应急处理:将传感器输出线短接,实际并不影响使用。