闪络电压,flashover voltage
1)flashover voltage闪络电压
1.Meanwhile, the factors which affect the flashover voltage of ceramic insulators were analyzed, the methods for improving the hold-off voltage were recommended from the in.本文介绍了关于真空中陶瓷绝缘子沿面闪络物理机制的各种假说,着重阐述了二次电子发射雪崩理论,分析了影响陶瓷绝缘子闪络电压的各种因素,提出了从陶瓷材料角度提高闪络电压的方向,总结了绝缘子沿面闪络现象的研究现状,展望了今后的研究方向与发展趋势。
2.The flashover performance of ice-covered XZP-210 insulator strings was investigated and the effects of the string length and arrangement on the icing flashover voltage were analyzed.结果表明:在不同污秽程度和气压下,轻度覆冰绝缘子串的正、负极性直流闪络电压与串长基本呈线性关系,但存在小于10%的非线性度,且污秽越严重或气压越低,非线性度越小;绝缘子串的布置方式对冰闪电压有明显影响,水平布置时冰闪电压最高,V型串次之,垂直串最低;气压对水平布置的绝缘子串冰闪电压影响最为严重,V型串次之,悬垂串最小。
3.Ice coating on overhead contact line not only will influence contact line’s sag and pole capability, but will influence the flashover voltage of insulator.接触网覆冰不仅影响接触线的弛度、支柱的容量,在一定程度上还影响着接触网绝缘子的闪络电压
英文短句/例句

1.fifty percent impulse flashover voltage百分之五十脉冲闪络电压
2.Flashover Voltage Forecasting Mode of Iced Insulator Based on RBF Network基于RBF网络的覆冰绝缘子闪络电压预测模型
3.Study on Flashover Voltage of Insulator Strings in High-temperature Water Vapor高温水蒸汽中绝缘子串闪络电压的研究
4.Experimental Study of the Raining Effect on Frequency Breakdown Voltage of Air-gap降雨对空气间隙工频闪络电压影响的试验研究
5.Dispersion of A.C. Artificial and Natural Pollution Flashover Voltage of High Voltage Insulators关于高压绝缘子交流人工和自然污秽闪络电压的分散性
6.Effects of Pre-polluting Manners on Artificial Icing DC Flashover Characteristics of Composite Insulators预染污方式对复合绝缘子人工覆冰直流闪络电压的影响
7.AC/DC FLASHOVER PERFORMANCE AND ITS VOLTAGE CORRECTION OF UHV INSULATORS IN HIGH ALTITUDE AND ICING AND POLLUTION ENVIRONMENTS高海拔、污秽、覆冰环境下超高压线路绝缘子交直流放电特性及闪络电压校正研究
8.Research of Lightning Over-Voltage in UHV Transmission Lines and Secondary Arc after the Single-Phase Trip-out Caused by Insulator-Flash;超高压输电线路雷电过电压及单相闪络跳闸后潜供电流的研究
9.Study on Calculation of Anti-Windage Yaw Flashover Performance for Ultra High Voltage Transmission Line;特高压输电线路抗风偏闪络性能的计算研究
10.Laser-triggered Flashover Characteristics of Nylon in the Air Condition with Pulsed Voltage脉冲电压下尼龙的激光触发沿面闪络特性
11.Study on Mechanism and Defend of Chopped Wave Overvoltage of Transformers Based on Insulator Arc-over;基于绝缘子闪络的变压器截波过电压机理及防护研究
12.Single-pulsed Surface Flashover Hold-off Voltage of Electrode Geometry in Vacuum真空中高压电极结构的单次脉冲沿面闪络耐压研究
13.Study on AC Icing Flashover Performance and Voltage Emendation of 10kV Composite Insulator in High Altitude Area;高海拔地区10kV合成绝缘子覆冰闪络特性及电压校正研究
14.Study on Flashover Performance and DC Discharge Model of Ice-covered Insulator Strings at Low Air Pressure低气压下覆冰绝缘子(长)串闪络特性及直流放电模型研究
15.Vacuum flashover developing across alumina ceramic at pulsed voltage真空冲击电压下氧化铝陶瓷沿面闪络现象的发展过程
16.Research on Voltage Flicker Detection and Flicker Source Identification电压波动与闪变检测及闪变源定向研究
17.Characteristics of Induced Overvoltage Generated by Triggered Lightning in the Low Voltage Power Supply System人工触发闪电引发的低压电源系统过电压特征
18.Quality of electric energy supply-Admissible voltage fluctuation and flickerGB12326-1990电能质量电压允许波动和闪变
相关短句/例句

voltage flashover电压闪络
3)dry flashover voltage干闪络电压
4)wet flash-over potential湿闪络电压
5)sparking potential闪电电压,闪络电压
6)50% flashover voltage gradient50%闪络电压梯度
延伸阅读

电压波动和电压闪变抑制电压波动和电压闪变抑制suppression of voltage fluctuation and flicker  d ianyabodong he dianyashan bion yizhi电压波动和电压闪变抑制(suppression。fvoltage fluetuation and flieker)冶金工厂中的电弧炉、大电动机、大电焊机等工作时,负荷电流的大幅度增减,引起电压急剧变化,其变化速度大于每秒。.2%,此时出现电压调幅波中的最高电压与最低电玉均方根值之差,称为电压波动。电压波动和有时伴随产生的电压闪变导致用电设备运行不稳定,照明闪烁,影响正常生产、生活甚至人身健康。因此,须对电压波动和闪变进行抑制,使其控制在允许范围内。 在中国按国家标准(GB12326一90)规定,电力系统公共供电点的电压波动允许值为:10kV及以下为2.5%,35~110kV为2.0%,220kV及以上为1.6%。在冶金工厂内部(非公共供电点),按本行业的有关规定,当电弧炉和轧钢大电动机由单独变压器供电时,其用电电压波动允许值可放宽到5%以内。 在电弧炉的熔化期,冲击性无功负荷产生快速的电压波动,使照明灯光发生闪烁,引起人的视觉疲劳而使情绪烦燥,还可能导致电视荧屏监控图像不稳、精密电子仪器工作不正常等。此种人的眼睛对于灯闪的主观感觉称为闪变。对闪变的程度,以对人的眼睛最为敏感的loHz频谱的等效闪变电压值△V10的大小来衡量和评价,按国家标准(GB12326一90)规定,电力系统公共供电点的允许△V10推荐值为:照明要求较高的白炽灯负荷为0.4%,一般性照明负荷为。,6%。 其抑制措施是:(l)对于轧机主传动的冲击性负荷,设计时采用减少电网感抗,以提高供电点的短路容量;或利用自备发电厂发电机,大型同步电动机(如高炉电动鼓风机)进行跟踪补偿;或将两个以上的冲击负荷在时间上错开;或设立单独的静止型动态无功补偿器等加以解决。后者有晶闸管开关电容器式(TSC)、晶闸管控制电抗器式(TCR)、晶闸管控制高阻抗变压器式(TCT)、自饱和电抗器式(SSR)、可控饱和电抗器式(CSR)、复合式(TCR十TSC)和自激变换器式(SVG)等多种类型。(2)对于电弧炉冲击性负荷,设计时采用减少电网感抗以提高供电点的短路容量;或设置单独的静止型动态无功补偿器等加以解决。由于电弧炉在熔化期三相负荷经常不平衡,闪变剧烈,要分相进行控制。要求补偿器响应速度快(全过程的响应时间应小于1个周波)参设计通常采用TCR、SSR、TCT和TCR二TSC等几种静止型动态无功补偿器。 (张炳炎)