空调机房,air conditioning unit plant room
1)air conditioning unit plant room空调机房
1.Retrofit of air conditioning unit plant room for broadcasting studios in Qingdao Guangdian Mansion;青岛广电大厦演播室空调机房的改造工程
英文短句/例句

1.The application of the coverter running of a circulating pump to save energy in the boiler’s air conditioning room;锅炉房空调机房循环泵变频调速节能运行的应用
2.Simulation of Air Distribution on Data Center and Port Traffic Stream空调机房气流分布和海上交通流的数值模拟
3.Discussion on Variable Flowrate Technology Based on Temperature Control in HVAC System质疑暖通空调机房温控变流量节能技术
4.Starting from the Room Air-conditioned Space to Open up a New Energy Saving从机房空调入手 开辟节能降耗新空间
5.Simulation of Precision Air Conditioning Liebert FH290A;机房专用空调力博特FH290A的模拟仿真
6.Design of Computer Room Air Conditioner Control System Based on μC/OS-II;基于μC/OS-II的机房空调测控系统设计
7.Application of FMS Theory on Air Conditioner Design and Manufacture;FMS机理在房间空调器生产上的应用
8.Design of the Machinery Room of Air Conditioning Heat/Cold Sources in Xianian Community of Jincheng City晋城市下辇社区空调冷热源机房设计
9.The selection and design of air supply for air conditioning used in telecommunication room电信机房空调送风方式的选择与设计
10.Feasibility analysis of energy-saving renovation in IDC plant in Langfang廊坊IDC机房空调节能改造可行性分析
11.A Simple Method of Installing Automatic Start-up Device to the Air-conditioner in the Computer Room计算机机房空调加装来电自动开机装置
12.Characteristics of Airflow Organization and Deployment Scheme of Air-Condition Cold Capacity in Communication Rooms通信机房的气流组织特性与空调冷量调配方案
13.Analysis on the Reason of Excessive Exhausting Pressure of Air-Condition Group in Computer-Room in Summer夏季机房空调机组排气压力过高原因分析
14.AHU selection for low?temperature air supply system and arrangement of plant room低温送风系统空调器的选用及机房布置
15.Research of Thermal Field Dynamic Response in Air-conditioning Room During Start-Up Process;空调房间开机过程温度场动态特性研究
16.The Feasibility Analysis of Air-conditioning Energy Saving Project联通机房科龙空调节能改造项目的可行性
17.Design of Energy Saving Reconstruction of Air-conditioning System in a Computer Room in Cold Region寒冷地区某计算机房空调系统节能改造设计
18.Review on Adjustment Mechanism of Rent and Vacancy Rate in Real Estate Market房地产市场租金与空置率调整机制研究述评
相关短句/例句

close control unit机房空调
1.Optimal design of constant temperature and humidity close control units;根据笔者的研发经验,结合制冷、供热、流体力学等基本原理,详细论述了机房空调制冷气流和控制系统关键部件的优化设计方案。
2.Foundation for design of constant temperature and humidity close control units;结合制冷、传热、流体力学等基本原理,详细介绍了机房空调的制冷、气流、控制系统的关键部件的计算、选型及设计方案。
3)computer room air conditioner(CRAC)机房空调机组
4)air conditioning machine room空调机室;空气调节机房
5)computer-room air conditioning system机房空调系统
1.In order to reduce the cost of computer-room air conditioning system in a whole year and to consider energy saving,this paper studied the flow of fresh air and a whole year s operation and regulation of this system.从节省机房空调系统全年运行费用、节约能源的角度出发,对新风量的控制及空调系统的全年运行调节进行了研究;提出了根据多工况的不同条件选择低能耗的空气处理方案,以及采用“新风焓值低于室内空气焓值时应尽量多取新风,否则尽量少取新风,并结合处理空气所需能耗”的新风量控制策略。
6)special air-conditioning in engine room机房专用空调
1.The paper emphatically anlyse distinction between special air-conditioning in engine room and comfortable air-conditioning in the field of appliction , describe importance of special air-conditioning in engine room.本文着重分析了电信机房空调与舒适性空调在应用上的差异,描述了机房专用空调的重要
延伸阅读

调度自动化计算机房调度自动化计算机房computer room of dis-patching automa-tion system  dis孙tehing automation system)调度所内计算机系统及有关设备的场所以及各种辅助用房。 机房组成调度所计算机系统机房由计算机机房和擂助机房组成。 (1)计算机机房.包括主计算机、前t计算机、磁盘机、磁带机、通信接口设备以及供维护开发用的程序员显示终端、操作控制台、打印机等的用房。大型计算机机房可专设计算机的专用电源配电柜,以及配套的辅助房间.包括维修室、仪器室、备件室、磁介质库、纸介质库、软硬件人员办公室等.如兼作离线计算使用,还得设t数据录人室、离线用户工作室等。 (2)辅助机房.包括空调机房、供电系统的UPS电探、配电室、蓄电池室、油机机房、控制室和值班室等。 机房设!的要求 (1)布局合理,有利于维护和使用,能为提高工作效率创造条件。 (2)尽t缩短设备之间的连线,以减少信号衰耗和延迟,并可减小传翰中的千扰。 (3)对特殊设备作专门安放,如对噪声大的行式打印机可在调度室附近专门设t输出设备室;对清洁度要求特别高的磁盘可在计算机房内设t专门的净化室等。 (4)符合技术安全及防火规范的要求。 机房的典型布I 调度所计算机系统机房的典型布里如图1所示. 机房的环境要求 (1)沮度一般分三级,大中型调度计算机房为A级,21士2℃;小型调度计算机房一般采用B级,21士5℃,调度室和其他枯助机房为C级,15~28℃. (2)湿度。大中型调度计算机房为A级,50%士10%;小型调度计算机房(徽机)为50%士20%。 (3)清洁度。一般分两级。大中型调度计算机房采用A级,指直径大于。、5林m以上的尘埃粒子,每立方英尺空气中应少于30~50万个;小型调度计算机房(徽机)采用B级,指直径大于。.51.1以上的尘埃粒子,每立方英尺空气中应少于100万个. (4)噪声。机房嗓声要求控制在“dB以下,而对调度室噪声还要进一步降低.具体措施为:①天花板采用吸音材料,坡壁要隔音,采用双层密闭门窗;②通风口装消声器;③嗓声大的行式打印机在调度室附近专设物出设备室, UPs专设电源室。 机房的供电和照明及接地 (1)供电.调度计算机系统均采用UPS供电,德频、德压的要求如表所示。供电系统如图2所示。