1)supply air rate送风量
1.Expressions must be used to determine the supply air rate.结论是 ,当工程的实际情况与规范编制送风量表的假定情况有较大差异时 ,应通过计算确定正压送风量 ;矩形风道断面的长宽比宜小于 6 ;在计算风压时当量绝对粗糙度修正系数取较大值 ,以应对施工过程中的一些不可预见因素 ;防烟楼梯间的地上部分和地下 (半地下 )部分的防排烟应分别考虑 ;楼梯间设置正压送风系统时 ,楼梯间设置的外窗应明确为固定窗 ;技术交底时应与土建施工管理人员进行沟通 ,确保建筑风道内表面严密、光滑。
2.Shortcomings of traditional method to test supply air rate of outlet of ductwork are pointed out.指出了传统的送风口送风量测试方法的不足,提出了一种新的送风口送风量测试方法,给出了新的送风口送风量测试装置的设计方法。
3.The results show that cooling capacity of the unit drops dramatically as the supply water temperature rises,and also drops as the supply air rate decreases.实验结果表明,被测机组的供冷量随供水温度升高而迅速下降,随送风量减少而下降。
英文短句/例句
1.The Study of Minimum Total Supply Air Volume Control in Variable Air Volume Air-conditioning System;变风量空调系统中最小总送风量控制的研究
2.Study on Air Supply Volume Prediction of Air-Conditioned Room Based on GA-ANN;基于遗传神经网络的空调房间送风量预测研究
3.Application of flow distribution method of equivalent circulation area to calculation of pressurized air supply“当量流通面积”流量分配法在加压送风量计算中的应用
4.This paper illustrates the design process of clean room ventilation and air-conditioning system, espe-cially the determination of the quantity of air supply.介绍了洁净室通风及空调系统的设计过程,主要的设计计算在于确定系统的送风量。
5.Experimental Research on Characteristics of Air Loop Duct in Variable Air Volume (VAV) Systems;变风量环形管道送风系统的实验研究
6.Study on Changing Dew-point Temperature of Supplying Air and Control for Variable Air Volume Air-Conditioning System;变风量空调变露点温度送风及控制研究
7.Optimal and Fault Tolerant Control of Supply Air Temperature in VAV Systems变风量空调系统送风温度优化及容错控制
8.Supply Air Diffuser Design of VAV System by ADPI采用ADPI方法选择变风量系统送风散流器
9.Rectification effects of orifice plate unit in the air volume testing equipment at two typed-sending风量试验台在不同送风方式下整流效果分析
10.Research of Boiler Air Flow Measurement in Power Plant火力发电厂锅炉送风流量测量方法研究
11.Numerical Study on Convecting Transfer Heat of Underfloor Air Supply;地板送风系统对流热转移量的数值研究
12.The Numerical Simulation Study of the Inner Flow in the Air-assisted Hydraulic Ultra-low Volume Sprayer Device;风送式超低量喷雾装置内流场数值模拟研究
13.The Experiment Research on Different Diffusers Influencing Thermal Comfort in VAV System;送风形式在变风量空调系统中对热舒适性影响的实验研究
14.Analysis of Air Supply Quality of Central Air-conditioning Ventilation System in Building before and after Cleaning集中空调通风系统清洗前后空调送风卫生质量分析
15.conditioned blast air空调鼓风,调温调湿送风
16.central supply and exhaust system集中送风和排风系统
17.Monitoring Measurement and Numerical Simulation on Highway Tunnel Shafts That Inhale and Exhaust Gas Though One Shaft公路隧道单井送排风式竖井施工监控量测及数值模拟分析
18.Numerical simulation of air quantity and pressure drop performance of perforated supply air terminals多孔板送风末端流量与管路阻力特性的数值模拟
相关短句/例句
air output送风量
3)supplied air volume送风量
1.Discusses issues in displacement ventilation including the relation of upward air supply and displacement ventilation, prediction of the thermal stratification level, determination of the temperature rises in near floor and working zones, and calculation of the supplied air volume.分析讨论了下部送风与置换通风的关系 ,热力分层高度的计算 ,地面空气层温升与工作区温升的确定 ,送风量计算等问
4)Steady air supply等量送风
5)fan delivery风扇送风量
6)degree of humidity in wind送风含湿量
1.At strong space of degree of humidity control in the system,PID of simple adoption control regulation,space of the temperature,degree of humidity proceeds solution coupling calculation,Space of opposite degree of humidity control the conversion is a control that degree of humidity in wind.在大空间的温度控制系统中 ,采用简单的PID控制规律 ,对空间的温度、湿度进行解藕计算 ,将空间的相对湿度控制转化为送风含湿量的控制。
延伸阅读
定风量阀在通风空调中的应用定风量阀,是一种机械式自力装置,适用于需要定风量的通风空调系统中。定风量阀风量控制不需要外加动力,它依靠风管内气流力来定位控制阀门的位置,从而在整个压力差范围内将气流保持在预先设定的流量上。 (一)在新风系统中的应用目前,在国内,风机盘管加新风系统的空调方式还是较普遍,尤其是宾馆客房部分,大部分写字楼、办公楼都采用这种方式。通常做法是每层设新风机组,走道敷设新风干管,几十根支管分别从总管上接入各房间。以宾馆客房为例,每间客房新风量一般为100m3/h,如何做到各支管的风量一致呢?一般来说,设计师往往会在新风支管上加设一只风量调节阀,期望通过后期调试手段来完成风量分配。由于新风系统一般情况下均为干管长,支管短,而风量调节阀调节既不直观,调节精度又不理想,况且每间客房新风量只有100m3/h,风量很小,这样的调试几乎是无法完成的。施工单位只能做到测一下新风干管的总送风量,保证各送风支管有风感这样的地步。为了能保证各房间所送新风量能达到设计值,也无需施工单位再去一个房间一个房间的平衡,我们只需在每支新风支管上加设一只定风量阀,以上问题就迎刃而解。在高层建筑内居住、办公的人常常抱忧新风量不足,而设计师往往感到很委屈。因为从图纸上看,新风量标准的取值并不低,但我们往往忽略了一个问题,如何从设计角度来保证实际效果,而定风量阀在新风系统中的应用,就是一个有力的措施。因目前定风量阀主要还是依靠进口,价格较贵,笔者建议在四、五星级宾馆,高档写字楼运用比较合适。 (二)在排风系统中的应用一个好的空调系统设计,它的排风系统必须很合理,而这一点往往得不到重视。在民用建筑特别是在高层建筑里,围护结构的气密性很好,只需较少的风量就可以维护房间的正压值。大约新风量的85~90%必须通过有组织的排风排出室外,这样才能保证送风、排风的风量平衡,否则再多的新风量也无法送进房间。在民用建筑里,排风一般通过卫生间、开水间等辅助用房排出室外。除此之外,有时还应再增加一套排风系统,才能保证送、排风平衡。对于卫生间排风,通常做法是每间卫生间设一、二只卫生间通风器,与排风竖井上的排风机联锁。我们知道,高层建筑内新风系统应该是一年四季都运行的,相应排风系统也应该是一年四季都运行的。也就是说,使用卫生间的人不可以去控制卫生间通风器的开启,设卫生间通风器的必要性就没有了。况且一个大风机带几十个小风机这样的排风系统运行既难匹配,又不经济。排风量为400m3/h的卫生间通风器噪音就有40dB左右,使卫生间失去宁静。大量的卫生间通风器也给维护带来很大的麻烦。为解决这个问题,我们可以取消卫生间通风器,在排风竖井每层支管上加设一只定风量阀,竖井顶部设一只排风机。这样的排风系统,能保证各层所排风量大致相等,而系统控制简单,运行可靠,卫生间可以很宁静。